Open Access


Read more
image01

Online Manuscript Submission


Read more
image01

Submitted Manuscript Trail


Read more
image01

Online Payment


Read more
image01

Online Subscription


Read more
image01

Email Alert



Read more
image01

Original Research Article | OPEN ACCESS

Ultrafast monolithic HPLC method for simultaneous quantification of the anticancer agents, imatinib and sorafenib: Application to tablet dosage forms

Hassan A Alhazmi1 , Dhaif Allah Moraya1, Emad Alahdal1, Mohammed Kariri1, Mohammed Al Bratty1, Ziaur Rehman1,2, Sadique A Javed1

1Department of Pharmaceutical Chemistry, College of Pharmacy, Jazan University, Jazan 45142, Saudi Arabia; 2Department of Pharmacy, IBMER, Mangalayatan University, 33rd Milestone, Beswan, Aligarh 202145, India.

For correspondence:-  Hassan Alhazmi   Email: haalhazmi@jazanu.edu.sa   Tel:+66541433344

Accepted: 17 May 2018        Published: 30 June 2018

Citation: Alhazmi HA, Moraya DA, Alahdal E, Kariri M, Bratty MA, Rehman Z, et al. Ultrafast monolithic HPLC method for simultaneous quantification of the anticancer agents, imatinib and sorafenib: Application to tablet dosage forms. Trop J Pharm Res 2018; 17(6):1127-1134 doi: 10.4314/tjpr.v17i6.20

© 2018 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To develop and validate a simple ultrafast monolithic high performance liquid chromatography (HPLC) method for the simultaneous quantification of two anti-cancer agents, imatinib and sorafenib, in pure form and tablet preparations.
Methods: Chromatographic separation was accomplished using Chromolith flash RP-18 HPLC-column (25 - 4.6 mm; macropores, 2 µm; mesopores, 13 – 15 nm). The optimum mobile phase composition of ammonium acetate buffer (10 mM, pH 8.5) and methanol at ratio of 35:65 v/v was used. Effluent flow rate was adjusted to 1.0 mL/min and the analysis was performed at 250 nm wavelength. The developed method was evaluated for specificity, linearity, precision and accuracy.
Results: The method offered a linear relationship over the concentration range of 1 - 16 µg/ml (correction coefficient, R2 = 0.9999) for both analytes. Limit of detection (LOD) was 0.1891 and 0.1888 µg/ml while limit of quantification (LOQ) was 0.6303 and 0.6294 µg/ml  for imatinib and sorafenib, respectively. Mean recovery was within 100 ± 2 %. The utility of the new method was demonstrated by its successful use for the analysis of commercially available tablet formulations of both drugs.
Conclusion: The developed method is fast and economical, and is being recommended for routine analysis of imatinib and sorafenib in bulk drug and tablet dosage forms in quality control laboratories.

Keywords: RP-HPLC, Chromolith, Imatinib, Sorafenib, Validation, Quality control

Impact Factor
Thompson Reuters (ISI): 0.523 (2021)
H-5 index (Google Scholar): 39 (2021)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates